ASTM D5236 PDF

The ASTM D method of distillation employs a vacuum pot still with a low pressure drop entrainment separator operated under total takeoff conditions. Distillation Combined semi-automatic ASTM D / D Semi-automatic fraction collector with 6 x 12 recievers. Ask for quotation for the Combined. Download Astm d Designation: D – 03 (Reapproved ) An American National Standard Standard Test Method for. Distillation of Heavy.

Author: Mukinos Yozshukasa
Country: Peru
Language: English (Spanish)
Genre: Travel
Published (Last): 11 October 2009
Pages: 65
PDF File Size: 9.29 Mb
ePub File Size: 20.8 Mb
ISBN: 538-1-45032-648-2
Downloads: 24006
Price: Free* [*Free Regsitration Required]
Uploader: Juk

If the rise in pressure is greater xstm 0. We need your help! This will take 2 to 10 min depending on the amount of material in the flask. This wettage may be treated as a separate asfm and its density estimated or blended into the residue before inspections are made.

Automatic or manual control can be used. Individual crude oil quality tests are also available on an individual basis. Alternatively, a tensimeter or certified electronic sensors may be used, provided the calibration of the sensor and its associated recording instrument can be traced back to a primary pressure standard.

Awtm from Table 2 the highest pressure that is d5326 with the expected initial boiling point as well as the lowest pressure that is consistent with the maximum cutpoint, using Fig. If solid waxy material appears on the walls, warm the receiver with an infrared heat wstm or hot air gun to liquify the product in the receiver in order to improve the accuracy of the reading. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

The external magnetic drive must be capable of rotating the bar in the flask when located directly below and touching the mantle. Send us a request Need help or have a question? Global Reach Intertek is the industry leader with over 42, people in 1, locations in over countries.

  INDIAN ART PARTHA MITTER PDF

Crude Oil Assay Tests List

Allow the residue to cool while stirring. Crude oil and petroleum quality expertise: Current edition approved Dec. It is NOTE 4—Cracking will significantly affect the quality of the cuts and the residue, for example, the densities and viscosities would be significantly ast than those obtained without cracking.

It provides an estimate of the yields of fractions of various boiling ranges.

High Vacuum (HIVAC) Still, ASTM D On H.S. Martin, Inc.

This test method employs a fractionating column having an efficiency of 14 to 18 theoretical plates operated at a reflux ratio of 5: Fit the distillation flask with a capillary line for the passage of nitrogen into the liquid. Laying the wire on the temperature sensor will then permit checking of this dimension. Weigh by difference to the nearest gram, the required volume of wet sample into a distillation flask containing a magnetic stirrer.

Discontinue heat input to the flask and heating jacket at once and slightly raise the pressure of the system by reducing the vacuum pump capacity. Summary of Test Method 4. Validating the specifications, value and safety of your raw materials, products and assets. Testing Evaluating how your products and services meet and exceed quality, safety, sustainability and performance standards.

Warning—Vapor temperature measurement is one of the two major sources of error in distillation data. Alternatively, the melt bath may have become contaminated or excessively oxidized. The use of two reference McLeod gages of different pressure ranges is recommended as a precaution. Inspection Validating the specifications, value and safety of your raw materials, products and assets.

The parts are connected by vacuumtight joints to facilitate servicing. This must be done bearing in mind the associated takeoff rates for the vacuum pressures indicated in Table 2 and the limitations of the pot temperature. Isolate the pump and the bleed valve. However, distillation curves and fraction qualities obtained by these methods are not comparable. A heat density of 0. Historical Version s – view previous versions of standard. The pressure should be lowered enough to allow the takeoff rate to accelerate briefly while the operator is remaining vigilant to avoid NOTE 2—Degassing of the charge is sometimes evident before the actual distillation begins.

  KRAKAU STADTPLAN PDF

In each case, this must be done keeping in mind the necessity to avoid starving the distillation due to a slow takeoff ratewhile at the same time avoiding entrainment by reducing too quickly the pressure applied to the system.

Crude Oil Assay Tests List

The values given in parentheses after SI units are provided for information only and are not considered standard.

A pressure of 0. Record the temperature when it becomes stable.

Warning— Measurement of vacuum operating pressure is one of the two FIG. Originally approved in Cuts are taken at preselected temperatures. Users must determine legality of sales in their location. Allow the system to stabilize adtm at least 2 min.

In the case of flasks too large to handle, the flask can be put in place and the charge drawn in from a container weighed with its transfer line using a pressure of 90 to 95 kPa in the still.

It shall be kept filled with aastm dry ice at all times while in service.

It shall be made of borosilicate glass and be totally enclosed in a silvered glass vacuum jacket having a permanent vacuum of less than 0. Preparation of Apparatus 8. Harmful or fatal if inhaled or ingested. Verification at least once a month is recommended.

Experience has shown that reduced crude oil samples typically run well at 0. Density must be measured in this case. In the case of glass flasks, the bottom shall be 4.